On titanium frameworks and alternative impression techniques in implant dentistry

Abstract
Purpose: The objectives of this thesis were to compare the clinical and material performance of implant-supported titanium frameworks with gold-alloy frameworks in the edentulous jaw and to test a digitized impression technique to optimize material characteristics and clinical and laboratory procedures.Materials and Methods: Two different kinds of laser-welded titanium frameworks and one type of digitized computer numeric controlled (CNC)-milled titanium framework for the edentulous jaw were evaluated and compared with gold-alloy frameworks in two clinical 5-year follow-up studies. The CNC frameworks were also evaluated and compared with gold-alloy frameworks in two experimental studies according to fit, preload, and surface roughness. Furthermore, a digitized photogrammetric technique for recording implant positions in the edentulous jaw was experimentally tested and compared with two conventional impression techniques.Results: Laser-welded titanium frameworks had a lower success rate after 5 years in function than gold-alloy frameworks. The 5-year performance of CNC frameworks was similar to that of gold-alloy frameworks. The fit and precision of implant-supported CNC frameworks was significantly better compared with gold-alloy frameworks. Applications of veneering material did not significantly affect the fit of the titanium frameworks. The preload of CNC frameworks was similar to that of gold-alloy frameworks, both exhibiting significantly decreased preloads after repeated tightening. The preloads of titanium frameworks were similar before and after veneering. Unloaded milled titanium screw sites had significantly rougher surfaces than loaded sites, and loaded gold screws had rougher surfaces than unloaded. No correlation between surface of the screw joints and preload of veneered titanium frameworks was observed. The precision of photogrammetric impressions was comparable to that of conventional impression techniques.Conclusions: Implant-supported CNC-milled titanium frameworks are a viable alternative to gold-alloy castings in the edentulous jaw, and because a digital platform is used to manufacture these titanium frameworks, photogrammetric impressions can be made.
University
Göteborgs universitet/University of Gothenburg
Institution
Department of Prosthetic Dentistry/Dental Technology
Avdelningen för oral protetik/odont materialvetenskap
Disputation
Föreläsningssal 3, Odontologiska fakulteten, Göteborg, kl. 09.00
Date of defence
2005-01-21
URI
http://hdl.handle.net/2077/16390
Collections
  • Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
View/Open
Pressmeddelande (2.930Kb)
Date
2004
Author
Örtorp, Anders 1964-
Keywords
Titanium
framework
computer numeric controlled
fit
surface roughness
and photogrammetry
Publication type
Doctoral thesis
ISBN
91-628-6169-7
Metadata
Show full item record

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV