dc.contributor.author | Carlsson, Charlotte | |
dc.contributor.author | Jonsson, Matilda | |
dc.date.accessioned | 2018-12-13T13:42:11Z | |
dc.date.available | 2018-12-13T13:42:11Z | |
dc.date.issued | 2018-12-13 | |
dc.identifier.uri | http://hdl.handle.net/2077/58420 | |
dc.description | The aim of the study was to examine acceptability of different listeners regarding children with speech sound disorder (SSD) and to analyze which speech deviances that occurred most in speech with low degree of acceptability. Validity and reliability were tested regarding this study’s type of audience response system (ARS) measuring acceptability. Speech material from 14 children with SSD and two children with typical speech, were used. The participants were eight children, 17 adult naive listeners and nine speech-language pathologists. A significant difference was shown between children and adult naive listeners (p=0,023) regarding degree of acceptability. Dentalization and voicing/devoicing occurred frequently in the speech with low degree of acceptability. Validity of the ARS system when measuring acceptability of this study’s listeners and SSD was tested in relation to a rating scale and the correlation was statistically significant, (r=0,91), inter- and intrajudge reliability were moderately good. | sv |
dc.description.abstract | Studiens syfte var att undersöka acceptabilitet hos olika lyssnare avseende barn med speech sound disorder (SSD) och att kartlägga vilka talavvikelser som är vanligt förekommande i tal med låg acceptabilitet. Validitet och reliabilitet prövades för studiens typ av audience response system (ARS) vid acceptabilitet. Talmaterial av 14 barn med SSD och två barn med typisk talutveckling användes. Lyssnare var åtta barn, 17 vuxna naiva lyssnare och nio logopeder. Signifikant skillnad visades mellan barn och vuxna naiva lyssnare (p=0,023) vad gällde grad av acceptabilitet. Dentalisering och avtoning/påtoning var vanligt förekommande i tal med låg grad av acceptabilitet. Validitet för ARS-systemet som mätinstrument för acceptabilitet för denna grupp av lyssnare och SSD prövades mot en skattningsskala och korrelationen var signifikant, (r=0,91), inter och intrabedömarreliabilitet var måttligt god. | sv |
dc.language.iso | swe | sv |
dc.relation.ispartofseries | 2018 | sv |
dc.relation.ispartofseries | 323 | sv |
dc.subject | acceptabilitet | sv |
dc.subject | speech sound disorder | sv |
dc.subject | audience response system | sv |
dc.subject | lyssnare | sv |
dc.subject | acceptability | sv |
dc.subject | listener | sv |
dc.title | Acceptabilitet avseende tal påverkat av speech sound disorder, kopplat till talavvikelser och olika lyssnargrupper | sv |
dc.title.alternative | Acceptability regarding speech affected by speech sound disorder, connected to deviations of speech and different groups of listeners | sv |
dc.type | Text | |
dc.setspec.uppsok | Medicine | |
dc.type.uppsok | H1 | |
dc.contributor.department | Göteborgs universitet/Institutionen för neurovetenskap och fysiologi | swe |
dc.contributor.department | Gothenburg University/Institute of Neuroscience and Physiology | en |
dc.type.degree | Student essay | |