On the role of number of fixtures, surgical technique and timing of loading
Abstract
Aims: The aims of this thesis were to analyze reduced number of implants supporting full arch fixed mandibular prostheses and fixed partial dentures (FPDs), non-submerged healing and early loading in the edentulous mandible. A further aim was to evaluate fit of Computer Numerical Control (CNC)-milled I-Bridge® frameworks.
Material & Methods: Paper I. One hundred and nineteen patients rehabilitated with full arch mandibular prostheses supported by four implants were evaluated after a mean follow-up of 4.4 years. Paper II. A total of 178 patients provided with FPDs supported by two (n=92) or three implants (n=122) of whom 123 were evaluated after a mean follow-up of 9.4 years. Paper III. Early and delayed loading of full arch mandibular prostheses were evaluated in 109 patients, 54 with delayed loading and 55 with early loading, with a mean follow-up of 3.6 years. Paper IV. Submerged and non-submerged implant placement for supporting fixed prostheses in the edentulous mandible were evaluated after five years in 29 patients. Paper V. The precision of fit of CNC milled I-Bridge® frameworks was evaluated using two different implant systems.
Results: Paper I. The five year cumulative survival rate (CSR) for implants was 99.1% and for prostheses 100%. Mean bone loss from baseline to five-year follow-up was 0.5 mm. No indication could be found that the number of supporting implants influenced the prosthetic complications. Paper II. The five year implant and prosthesis CSR was 97.7% for 2-implant supported FPDs and 97.0% for 3-implant supported FPDs. Mean bone loss at five years was 0.4 mm. Significantly more prosthetic and abutment screw loosening were seen in two-implant supported FPDs. Paper III. Five year CSR for implants was 94.4% and 92.5% for prostheses in early loading, and 97.9% and 98.0% in the delayed loading group. More prostheses needed adjustment or replacement in the early group, but patients treated with early loading were more pleased with the treatment procedure. Paper IV. Five-year CSR survival rate was 99.4%. Three implants fractured in one patient. Mean bone loss at five years was 0.5 mm in submerged implants and 0.4 mm in non-submerged implants. Paper V. All frameworks demonstrated clinically acceptable fit with mean distortion values within 23 μm (x-axis), 26 μm (y), 4 μm (z- axis) and 34 μm (3-D) for all frameworks. Control frameworks displayed greater levels of distortion than frameworks produced in a strict test situation.
Conclusion: A reduction of the number of supporting implants to four implants in full arch mandibular prostheses and two implants in three unit FPDs in partial edentulous jaws resulted in the same clinical outcome as when more implants are used. Non-submerged implant placement in the edentulous mandible was as predictable as submerged, but early loading of implant supported mandibular prostheses incurred more prosthetic complications. Computer numerical control (CNC)-milled frameworks presented levels of precision of fit within limits considered to be clinically acceptable and superior to earlier published results on cast frameworks.
Key words: Computer numerical control, dental implants, fixed prostheses, non-submerged
ISBN: 978-91-628-7467-4; ISSN: 0348-6672; Swedish Dental Journal Supplement 197, 2008
Correspondence: Alf Eliasson, Department of Prosthetic Dentistry, Postgraduate Dental Education Center Örebro, Sweden; email: alf.eliasson@orebroll.se
Parts of work
Eliasson A, Palmqvist S, Svenson B, Sondell K. Five-year results with fixed complete-arch mandibular prostheses supported by 4 implants. Int J Oral Maxillofac Implants 2000;15:505-510. ::pmid::10960983 Eliasson A, Eriksson T, Johansson A, Wennerberg A. Fixed partial prostheses supported by 2 or 3 implants: A retrospective study up to 18 years. Int J Oral Maxillofac Implants 2006;21:567-574. ::pmid::16955607 Eliasson A, Blomqvist F, Johansson A, Wennerberg A. A retrospective analysis of early and delayed loading of full-arch mandibular prostheses using three different implant systems: Clinical results up to 5 years of loading. Clin Implant Dent Rel Res. In Press. ::pmid::18384397 Eliasson A, Narby B, Ekstrand K, Hirsch J, Johansson A, Wennerberg A. A 5-year prospective clinical study of treatments with implant-supported fixed prostheses in the edentulous mandible using the Paragon System Implants placed according to a submerged and non-submerged surgical protocol. Submitted for publication. Eliasson A, Wennerberg A, Johansson A, Örtorp A, Jemt T. The precision of fit of milled titanium implant frameworks (I-Bridge®) in the edentulous jaw. Submitted for publication.
Degree
Doctor of Philosophy (Odontology)
University
University of Gothenburg. Sahlgrenska Academy
Institution
Inst of Odontology. Dept of Prosthetic Dentistry/Dental Material Science
alf.eliasson@orebroll.se
Date
2008-05-13Author
Eliasson, Alf
Keywords
Computer numerical control
dental implants
fixed prostheses
non-submerged
CNC-milling
Publication type
Doctoral thesis
ISBN
978-91-628-7467-4
ISSN
0348-6672
Language
eng