Diagnosing and monitoring open-angle glaucoma. Pupillometry and other novel techniques

Abstract
Aim:To investigate the ability of a custom-built pupillometer and other novel diagnostic instruments to detect and monitor optic nerve damage in glaucoma.Methods:In the first two studies we investigated pupillary reactions to light in patients with glaucoma and in healthy persons using a custom-built pupillometer. In the first study, comprising 32 subjects, light reflexes were studied with five different sets of stimulus-pause combinations in order to find the optimum stimulus parameters. Using these parameters we examined 65 participants in the second study. In the third study frequency doubling technology perimetry (FDT) was compared with high-pass resolution perimetry (HRP) in 162 eyes. In the fourth study we conducted a long-term follow-up study of 25 persons with glaucoma and 34 with ocular hypertension in which we analyzed glaucomatous optic disc changes using Heidelberg Retina Tomography (HRT). Results:Study I-II: Alternating light stimulation with 0.5 sec stimulation and 1 sec darkness was shown to be optimum for detection of relative afferent pupillary defect (RAPD) in glaucoma. Quantification of RAPD based on calculations of pupil area ratio (PAR) was found to be the most sensitive for glaucoma detection. Study III: A strong correlation was found between FDT and HRP. Sensitivity and specificity of the FDT screening test for glaucoma detection were 92% and 88%, respectively.Study IV: Several HRT parameters showed significant difference between baseline and follow-up examination in a group of patients with progressive glaucomatous neuropathy. A well-defined distinction between the progressive and the stable group was found by comparing digitally processed HRT change images.Conclusions:Both pupillometry and FDT screening perimetry could distinguish eyes with glaucoma from normal eyes with a good sensitivity and specificity. HRT proved useful for long-term follow-up of glaucomatous optic neuropathy and is an important adjunct to optic disc photography and visual field test for the monitoring of glaucoma progression.
University
Göteborgs universitet/University of Gothenburg
Institution
The Sahlgrenska Academy
Sahlgrenska akademin, Institutionen för neurovetenskap och fysiologi, Sektionen för klinisk neurovetenskap och rehabilitering
Disputation
Psykiatriska klinikens aula, Hus V, Sahlgrenska Universitetssjukhuset/Mölndal, kl. 09.00
Date of defence
2006-05-10
URI
http://hdl.handle.net/2077/16800
Collections
  • Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
View/Open
Pressmeddelande (1.994Kb)
Date
2006
Author
Kalaboukhova, Lada 1975-
Keywords
open-angle glaucoma
relative afferent pupillary defect
pupillometer
visual field
Frequency Doubling Technology Perimetry
High-pass Resolution Perimetry
Heidelberg Retina Tomography
Publication type
Doctoral thesis
ISBN
91-628-6787-3
Metadata
Show full item record

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV