Visa enkel post

dc.contributor.authorHjalmarsson, Lars
dc.date.accessioned2009-11-22T17:07:03Z
dc.date.available2009-11-22T17:07:03Z
dc.date.issued2009-11-22T17:07:03Z
dc.identifier.isbn978-91-628-7923-5
dc.identifier.issn0348-6672
dc.identifier.otherSwedish Dental Journal Supplement 201, 2009
dc.identifier.urihttp://hdl.handle.net/2077/21179
dc.description.abstractBackground: Cobalt-chrome (CoCr) alloys have been used in dentistry in decades but very little is known about their behavior and biological impact as framework materials in implant dentistry. Furthermore, few studies have evaluated and compared the clinical and radiological results of abutment and abutment-free implant treatment concepts. Aims: To investigate in vitro CoCr and commercially pure (CP) titanium frameworks regarding precision of fit, estimated material degradation and possible adverse cellular responses. In addition, to retrospectively evaluate the clinical and radiological five-year outcome of abutment-free porcelain-veneered CoCr prostheses compared to acrylic-veneered CP titanium prostheses, with or without abutments. Materials and methods: Paper I. Two groups of cast, sectioned and laser-welded frameworks were fabricated, either in a CoCr alloy or in CP titanium. A third group comprised computer numeric controlled (CNC) milled CP titanium frameworks. Measurements of fit were performed with a coordinate measuring machine. Paper II. Ion leakage from titanium implants, CoCr and CP titanium framework sections into artificial saliva was observed with mass spectrometry. Surface structures were registered with optical interferometry. Paper III. Viability of epithelial cells and fibroblasts cultured on CoCr and titanium specimens were evaluated with the Alamar Blue™ method. Specimen surface structures were registered with optical interferometry and cell morphology observed with SEM. Paper IV. A test group (n=40) comprised of patients treated with prostheses made at implant level in dental-porcelain veneered CoCr alloy (n=15) or acrylic-veneered CP titanium (n=25). A control group (n=40) was provided with prostheses made at abutment level, in acrylic-veneered CNC-milled CP titanium. Clinical and radiological five-year data were evaluated. Results: Paper I. The transversal width decreased in CoCr frameworks, but increased in both groups of titanium frameworks. Less vertical distortions were present in the CNC-milled frameworks compared to the two other groups. Paper II. Significantly more cobalt ion leaked than titanium and chrome ions. Both framework sections and implants roughened after saliva exposure. Paper III. Both cell groups were more viable on titanium than on CoCr surfaces. The CoCr surfaces had a lower height deviation but were denser than the CP titanium surfaces. No major deviations from normal cell morphology were present. Paper IV. No significant differences in implant cumulative survival rates were demonstrated between the test and control groups after five years in function (98.6% and 97.6%, respectively). No major differences in bone levels were demonstrated. Mucositis and veneer fracture were the most common complications in all groups. Conclusions: None of the frameworks presented a perfect, completely “passive fit”. There were indications of active corrosive processes for both implants and framework materials. Epithelial cells and fibroblasts preferred titanium to CoCr surfaces. The clinical outcomes of implant level prostheses made of porcelain-veneered CoCr or acrylic-veneered titanium seem comparable to acrylic-veneered titanium prostheses made at abutment level.en
dc.language.isoengen
dc.relation.haspartI Hjalmarsson L, Örtorp A, Smedberg J-I, Jemt T. Precision of Fit to Implants: A Comparison of Cresco™ and Procera® Implant Bridge Frameworks. Clinical Implant Dentistry and Related Research, in press ::pmid::19438959en
dc.relation.haspartII Hjalmarsson L, Smedberg J-I, Wennerberg A. Material degradation in implantretained cobalt-chrome and titanium frameworks. Submitted for publication.en
dc.relation.haspartIII Hjalmarsson L, Smedberg J-I, Aronsson G, Wennerberg A. Cellular responses to cobalt-chrome and CP titanium: an in vitro comparison of frameworks for implantretained oral prostheses. Submitted for publication.en
dc.relation.haspartIV Hjalmarsson L, Smedberg J-I, Pettersson M, Jemt T. Implant level Cresco-prostheses in the edentulous upper jaw. A comparison with conventional abutment level prostheses after 5 years in function. Submitted for publication.en
dc.subjectcobalt-chromeen
dc.subjecttitaniumen
dc.subjectimplantsen
dc.subjectmisfiten
dc.subjectcorrosionen
dc.subjectviabilityen
dc.subjectabutment-freeen
dc.titleOn cobalt-chrome frameworks in implant dentistryen
dc.typetexteng
dc.type.svepDoctoral thesiseng
dc.gup.maillars.hjalmarsson@dll.seen
dc.type.degreeDoctor of Philosophy (Odontology)en
dc.gup.originUniversity of Gothenburg. Sahlgrenska Academyen
dc.gup.departmentInstitute of Odontology. Department of Prosthetic Dentistry/Dental Material Scienceen
dc.gup.defenceplaceFredagen den 11 december 2009, kl. 9.00, Föreläsningssal 3, Odontologen, Medicinaregatan 10en
dc.gup.defencedate2009-12-11
dc.gup.dissdb-fakultetSA


Filer under denna titel

Thumbnail
Thumbnail

Dokumentet tillhör följande samling(ar)

Visa enkel post