Patient Safety in the OR - Focus on Infection Control and Prevention

Abstract
Aims: The overall purpose of this thesis was, in the light of patients’ experiences of acquiring a deep SSI, to explore the air quality during orthopedic implant surgery and the application of intraoperative measures to reduce risk factors associated with SSI. Methods: In Paper I, 14 patients were interviewed using a qualitative approach. In Papers II and IV, during elective and fracture implant operations, 284 active air sam-ples were taken in displacement and laminar (unidirectional) airflow-ventilated operat-ing rooms. Door openings and other events occurring during surgery were recorded. In Paper III, to obtain data on the application of infection-prevention measures, structured and participant observations were carried out during 69 surgical procedures. Results: Paper I, revealed that developing a deep infection after surgery was seen as a life-changing event, negatively affecting all parts of life. Feelings of pain and not being taken seriously by the health-care providers dominated the experiences. Paper II found that the mean levels of CFU/m3 in displacement-ventilated ORs exceeded the recom-mended levels for implant surgery (m=15.9). A strong correlation was found between door-opening rates (m=17.4) and CFU levels (r=0.74, p=0.001). Every door opening resulted in an increase in CFU/m3 of 5.3. Sixty-eight percent of the variance in CFU/m3 could be explained by: length of surgery, door openings and the number of people present in the OR. Paper IV showed that the laminar airflow system observed in this study offered high air quality with very low levels of CFU/m3 during surgery (md=1.0). No significant relationship between door openings and CFU/m3 was ob-served, but the median door-opening rate was found to be low (md=8). Paper III revealed that evidence-based measures, such as the correct timing of prophylactic antibiotics and normothermia to reduce the risk of postoperative infections, were not sufficiently implemented. The overall adherence to hand hygiene guidelines was 10.3%. Conclusions: Every unnecessary door opening and failure to implement protective measures during surgery potentially enables the development of an SSI that could result in serious consequences for the patient. Using patients’ narratives as a diagnostic tool could reduce the risk of delayed treatment. Finally, without a display in every OR that shows the current airflow and pressure gradient, the safety of patients cannot be guaranteed.
Parts of work
I. Andersson EA, Bergh I, Karlsson J, Nilsson K. Patients' experiences of acquiring a deep surgical site infection: An interview study. American Journal of Infection Control. 2010Nov;38(9):711-7. ::doi::10.1016/j.ajic.2010.03.017
 
II. Andersson EA, Bergh I, Karlsson J, Eriksson BI, Nilsson K. Traffic-flow in the operating room – an explorative and descriptive study on air quality during orthopedic trauma implant surgery. American Journal of Infection Con-trol. 2012 Oct;40(8):750-5 ::doi::10.1016/j.ajic.2011.09.015
 
III. Andersson EA, Bergh I, Karlsson J, Eriksson BI, Nilsson K. The application of evidence-based measures to reduce surgical site infections during orthopedic surgery - report of a single-center experience in Sweden. Patient Safe-ty in Surgery. 2012 Jun 14;6(1):1. ::doi::10.1186/1754-9493-6-11
 
IV. Andersson EA, Bergh I, Karlsson J, Eriksson BI, Nilsson K. Exploring the protective ability of parallel airflow systems (in manuscript).
 
Degree
Doctor of Philosophy (Health Care Sciences)
University
University of Gothenburg. Sahlgrenska Academy
Institution
Institute of Health and Care Sciences
Disputation
Fredagen den 3 maj 2013, kl 9.00, hörsal 2118, Institutionen för Vårdvetenskap och hälsa, Arvid Wallgrens backe hus 2, Göteborg
Date of defence
2013-05-03
E-mail
annette.erichsen@vgregion.se
URI
http://hdl.handle.net/2077/32002
Collections
  • Doctoral Theses / Doktorsavhandlingar Institutionen för vårdvetenskap och hälsa
  • Doctoral Theses from Sahlgrenska Academy
  • Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
View/Open
Thesis frame (19.17Mb)
Abstract (89.45Kb)
Date
2013-04-17
Author
Erichsen Andersson, Annette
Keywords
Patient safety
Patients' experiences
Surgical site infections
operationg room
Culture
Air sampling
ventilation systems
Publication type
Doctoral thesis
ISBN
978-91-628-8638-7
Language
eng
Metadata
Show full item record

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV