Trochanteric Hip Fractures Clinical Outcomes and the Cut-out Complication

Abstract
The established treatment for trochanteric hip fractures is internal fixation, either intramedullary (nail) or extramedullary (plate). Approximately 10% of these patients suffer from mechanical complications, the most frequent one being perforation of the lag screw through the femoral head into the hip joint (cut-out). This condition is painful and disabling, and requires revision surgery. The purpose of this thesis was to gain better understanding of the cut-out complication. The complication rate was evaluated in the retrospective series of 3066 consecutive patients treated with an intramedullary nail in a single centre over a 12 years period. Cut-out was found to be the most frequent complication albeit lower than in previous literature - 1.85% (57 patients) (Studies I and II). Combination of three factors: a comminute fracture, poor fracture reduction and non-optimal implant positioning was associated with an increased cutout risk. From the range of cut-out patterns, i.e. screw cut-out in a variety of paths through the femoral head, it was observed to be a three-dimensional event. To further analyse the pre-cut-out movements, Radiostereometric Analysis (RSA) method was applied in trochanteric hip fractures treated with intramedullary nails (Studies III and IV). Firstly, an experimental study was undertaken to confirm the applicability of RSA in trochanteric fractures. A SawbonesTM model of a trochanteric fracture was mounted on micrometer screws, and radiographed with different true reference displacements. RSA was shown to have high precision and accuracy in this application as translations and rotations in the fracture-implant model could be detected to within ±0.14mm and ±0.03mm (translations), and ±0.5° and ±0.18° (rotations). The last study prospectively evaluated the 3D fracture-implant movements with the RSA method in 20 patients with stable trochanteric fractures treated with an intramedullary nail and followed for one year. Fracture-implant motion decreased after 3 months and no cut-out occurred. RSA detected clinically relevant movements: translation of the proximal tip of the lag screw in the femoral head, femoral head and lag screw movements relative to the nail. It is important to recognize the "fracture at risk" and, particularly in these patients, achieve anatomical fracture reduction and optimal implant placement. The migration of the implant in bone measured by RSA could be used as a cut-out predictor and enable evaluation of new treatment methods in small groups of patients.
Degree
Doctor of Philosophy (Medicine)
University
University of Gothenburg, Institute of Clinical Science at Sahlgrenska Academy
Institution
Department of orthopaedics
Disputation
2014
Date of defence
2014-02-01
URI
http://hdl.handle.net/2077/54125
Collections
  • Doctoral Theses / Doktorsavhandlingar Institutionen för kliniska vetenskaper
  • Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
View/Open
Thesis (4.431Mb)
Date
2017-10-24
Author
Bojan, Alicja Joanna
Keywords
trochanteric hip fracture
cut-out
intramedullary fixation
RSA
micromotion
Publication type
doctoral thesis
ISBN
978-91-628-9231-9
Language
eng
Metadata
Show full item record

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV