Pulmonary ventilation and perfusion assessed by electrical impedance tomography - Experimental studies in pigs

Abstract
Pulmonary ventilation and perfusion and ventilation/perfusion (V/Q) matching determine gas exchange in every lung unit in the healthy state and in the pathologically altered lung. Mismatch of V and Q lead to hypoxaemia and hypercapnia and monitoring of V/Q relations are thus important in critical illness. This thesis focuses on electrical impedance tomography (EIT) to monitor pulmonary perfusion and its relation to ventilation in physiological conditions and in endotoxinaemic acute lung injury (ALI) in a porcine experimental model. EIT is a non-invasive, non-radiant continuous monitoring technique generating images of impedance distribution changes within the thorax. Blood and air differ considerably in impedance properties, resulting in characteristic distribution images of pulmonary ventilation and perfusion respectively. The methodology of assessing global perfusion by EIT was evaluated in the healthy state during interventions resembling acute hypovolaemia and recruitment manoeuvres. The pulse synchronous amplitude of systolic impedance change, measured during apnoea, correlated to a wide range of stroke volumes measured by the pulmonary artery catheter, as an estimate of pulmonary perfusion. The methodology was expanded to include regional perfusion and its relation to ventilation by combined measurements during apnoea and ventilation, generating estimates of V/Q relations. Global EIT measurements correlated significantly to venous admixture and alveolar dead space calculated by standard methods. Regional EIT measurements of V and Q provided physiologically relevant results under dynamic conditions. The monitoring technique was applied in pigs subjected to endotoxinaemic ALI to assess changes in regional V and Q and V/Q matching. V/Q mismatch developed primarily as a result of dorsal redistribution and increased heterogeneity of perfusion. Finally, pre-treatment with the angiotensin-converting enzyme (ACE) inhibitior enalapril to reduce angiotensin II levels and attenuate inflammation and V/Q mismatch in endotoxinaemic ALI was examined, employing EIT monitoring. The investigation failed to provide support for the hypothesis that ACE inhibition could improve V/Q mismatch and thus gas exchange. In conclusion, this thesis described that the EIT technique could be used to assess global and regional pulmonary perfusion and its relation to ventilation in physiological as well as pathological conditions Key words: electrical impedance tomography, pig, V/Q matching, endotoxinaemic ALI, ACE inhibitor ISBN 978-91-628-7853-5
Parts of work
I. Fagerberg A, Stenqvist O, Åneman A. Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model. Acta Anaesthesiol Scand 2009; 53 (2): 152-8 ::doi::10.1111/j.1399-6576.2008.01847.x
 
II. Fagerberg A, Stenqvist O, Åneman A. Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model. Critical Care 2009; 13(2): R34 ::doi::10.1186/cc7741
 
III. Fagerberg A, Sondergaard S, Karason S, Åneman A. Electrical impedance tomography can be used to assess the heterogeneity of pulmonary ventilation and perfusion during an acute lung injury in pigs. Accepted Acta Anaesthesiol Scand 2009
 
IV. Fagerberg A, Sondergaard S, Casselbrant A, Åneman A. Angiotensin-converting enzyme inhibition during endotoxinaemic acute lung injury in pigs does not affect ventilation/perfusion changes monitored by electrical impedance tomography. Submitted
 
Degree
Doctor of Philosophy (Medicine)
University
University of Gothenburg. Sahlgrenska Academy
Institution
Institute of Clincial Sciences. Department of Anesthesiology & Intensive Care Medicine
Disputation
Fredagen den 18 september 2009, kl. 9.00, hörsal LMC, Medicinaregatan 13, Göteborg
Date of defence
2009-09-18
E-mail
anneli.fagerberg@aniv.gu.se
URI
http://hdl.handle.net/2077/20462
Collections
  • Doctoral Theses / Doktorsavhandlingar Institutionen för kliniska vetenskaper
  • Doctoral Theses from Sahlgrenska Academy
  • Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
View/Open
Thesis frame (7.200Mb)
Abstract (108.2Kb)
Thesis cover (1.813Mb)
Date
2009-08-28
Author
Fagerberg, Anneli
Keywords
electrical impedance tomography
V/Q matching
pig
endotoxinaemic ALI
ACE inhibitor
Publication type
Doctoral thesis
ISBN
978-91-628-7853-5
Language
eng
Metadata
Show full item record

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV