Jämförelse mellan ”Auditory Brainstem Response (ABR) och ”Auditory Steady State Response” (ASSR) för att uppskatta hörtrösklar på barn i narkos. Kan testtiden minska om 500 Hz utesluts vid ASSR-mätning?
Comparison between Auditory Brainstem Response (ABR) and Auditory Steady State Response (ASSR) for estimated hearing thresholds of children under general anesthetics. Could the test duration be reduced by excluding 500 Hz in the ASSR measurement?
Abstract
Objective
The objective of this study was to investigate the clinical application to use ASSR in anesthetized children
Design
One main ambition of the investigation was to compare hearing threshold using ABR with estimated hearing threshold using ASSR. Another aim was to examine if the duration of an ASSR measurement could be reduced by only using the frequencies 1, 2 and 4 kHz and exclude the frequency 0.5 kHz. This is a retrospective study using electrophysiological measurement from a database.
Result
Results showed a high correlation between hearing threshold using ABR and estimated thresholds using ASSR, with the frequency 0.5 kHz showing a slightly lower correlation. Result also showed that the test duration was increased when using all test frequencies in ASSR-measurement compared to when 0.5kHz was excluded.
Conclusion
The study showed a high correlation when comparing hearing threshold using ABR and ASSR. Although the frequency 0.5 kHz showed a slightly lower correlation, it should still be included in the tests because it supplies vital information about the bass region
The mean test duration for both types of hearing threshold measurements on anesthetized children was 56 minutes. This is a reasonable time to use on anesthetized children. The test duration was reduced when excluding the test frequency 0.5kHz in ASSR-measurement. The relatively short duration required for both test methods is enabled by the absence of disturbances when testing children under general anesthetics. ABR and ASSR should both be used together when estimating threshold in anesthetized children.
Degree
Student essay
Collections
View/ Open
Date
2010-12-21Author
Wallström-Berg, Birgitta
Keywords
Auditory brainstem response, auditory steady state response, narkos, dikotisk, 90 Hz ASSR
Auditory Brainstem Response, Auditory Steady State Response, Anesthetic Children, Dikotic, 90 Hz ASSR
Series/Report no.
Uppsats
Language
swe
Metadata
Show full item recordRelated items
Showing items related by title, author, creator and subject.
-
En studie av skillnader mellan monotisk och dikotisk 40 Hz Auditory Steady-State Response
Brolin, Andreas; Söderberg, Axel (2009-06-10)Objective The objective of this study was to investigate differences between monotich and dichotic 40 Hz Auditory Steady-State Response (ASSR) with Interacoustics Eclipse. Design The aspects studied are test duration, ... -
Impact of IVIS on driving performance and safety on the road
Yordanov, Zlati; Hussain, Asif (2010-09-24)Automatic Speech Recognition is a state-of-the-art technology which is changing the way people interact with computers nowadays. Automotive industry profits from this technology while using it for controlling the in-vehicles ... -
Översättning och utvärdering av det bildbaserade förståelsetestet TACL-3 - en pilotstudie
Christensen, Katarina; Edner, Frida (2011-09-21)Test for Auditory Comprehension of Language -3 is an American picturebased test developed to examine children’s auditory comprehension of language. The aim of the study was to create a translation and to examine if the ...