• English
    • svenska
  • svenska 
    • English
    • svenska
  • Logga in
Redigera dokument 
  •   Startsida
  • Sahlgrenska Academy / Sahlgrenska akademin
  • Institute of Odontology / Institutionen för odontologi
  • Doctoral Theses / Doktorsavhandlingar Institutionen för odontologi
  • Redigera dokument
  •   Startsida
  • Sahlgrenska Academy / Sahlgrenska akademin
  • Institute of Odontology / Institutionen för odontologi
  • Doctoral Theses / Doktorsavhandlingar Institutionen för odontologi
  • Redigera dokument
JavaScript is disabled for your browser. Some features of this site may not work without it.

On cobalt-chrome frameworks in implant dentistry

Sammanfattning
Background: Cobalt-chrome (CoCr) alloys have been used in dentistry in decades but very little is known about their behavior and biological impact as framework materials in implant dentistry. Furthermore, few studies have evaluated and compared the clinical and radiological results of abutment and abutment-free implant treatment concepts. Aims: To investigate in vitro CoCr and commercially pure (CP) titanium frameworks regarding precision of fit, estimated material degradation and possible adverse cellular responses. In addition, to retrospectively evaluate the clinical and radiological five-year outcome of abutment-free porcelain-veneered CoCr prostheses compared to acrylic-veneered CP titanium prostheses, with or without abutments. Materials and methods: Paper I. Two groups of cast, sectioned and laser-welded frameworks were fabricated, either in a CoCr alloy or in CP titanium. A third group comprised computer numeric controlled (CNC) milled CP titanium frameworks. Measurements of fit were performed with a coordinate measuring machine. Paper II. Ion leakage from titanium implants, CoCr and CP titanium framework sections into artificial saliva was observed with mass spectrometry. Surface structures were registered with optical interferometry. Paper III. Viability of epithelial cells and fibroblasts cultured on CoCr and titanium specimens were evaluated with the Alamar Blue™ method. Specimen surface structures were registered with optical interferometry and cell morphology observed with SEM. Paper IV. A test group (n=40) comprised of patients treated with prostheses made at implant level in dental-porcelain veneered CoCr alloy (n=15) or acrylic-veneered CP titanium (n=25). A control group (n=40) was provided with prostheses made at abutment level, in acrylic-veneered CNC-milled CP titanium. Clinical and radiological five-year data were evaluated. Results: Paper I. The transversal width decreased in CoCr frameworks, but increased in both groups of titanium frameworks. Less vertical distortions were present in the CNC-milled frameworks compared to the two other groups. Paper II. Significantly more cobalt ion leaked than titanium and chrome ions. Both framework sections and implants roughened after saliva exposure. Paper III. Both cell groups were more viable on titanium than on CoCr surfaces. The CoCr surfaces had a lower height deviation but were denser than the CP titanium surfaces. No major deviations from normal cell morphology were present. Paper IV. No significant differences in implant cumulative survival rates were demonstrated between the test and control groups after five years in function (98.6% and 97.6%, respectively). No major differences in bone levels were demonstrated. Mucositis and veneer fracture were the most common complications in all groups. Conclusions: None of the frameworks presented a perfect, completely “passive fit”. There were indications of active corrosive processes for both implants and framework materials. Epithelial cells and fibroblasts preferred titanium to CoCr surfaces. The clinical outcomes of implant level prostheses made of porcelain-veneered CoCr or acrylic-veneered titanium seem comparable to acrylic-veneered titanium prostheses made at abutment level.
Delarbeten
I Hjalmarsson L, Örtorp A, Smedberg J-I, Jemt T. Precision of Fit to Implants: A Comparison of Cresco™ and Procera® Implant Bridge Frameworks. Clinical Implant Dentistry and Related Research, in press ::pmid::19438959
 
II Hjalmarsson L, Smedberg J-I, Wennerberg A. Material degradation in implantretained cobalt-chrome and titanium frameworks. Submitted for publication.
 
III Hjalmarsson L, Smedberg J-I, Aronsson G, Wennerberg A. Cellular responses to cobalt-chrome and CP titanium: an in vitro comparison of frameworks for implantretained oral prostheses. Submitted for publication.
 
IV Hjalmarsson L, Smedberg J-I, Pettersson M, Jemt T. Implant level Cresco-prostheses in the edentulous upper jaw. A comparison with conventional abutment level prostheses after 5 years in function. Submitted for publication.
 
Examinationsnivå
Doctor of Philosophy (Odontology)
Universitet
University of Gothenburg. Sahlgrenska Academy
Institution
Institute of Odontology. Department of Prosthetic Dentistry/Dental Material Science
Disputation
Fredagen den 11 december 2009, kl. 9.00, Föreläsningssal 3, Odontologen, Medicinaregatan 10
Datum för disputation
2009-12-11
E-post
lars.hjalmarsson@dll.se
URL:
http://hdl.handle.net/2077/21179
Samlingar
  • Doctoral Theses / Doktorsavhandlingar Institutionen för odontologi
  • Doctoral Theses from Sahlgrenska Academy
  • Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
Fil(er)
Abstract (19.67Kb)
Thesis frame (14.17Mb)
Datum
2009-11-22
Författare
Hjalmarsson, Lars
Nyckelord
cobalt-chrome
titanium
implants
misfit
corrosion
viability
abutment-free
Publikationstyp
Doctoral thesis
ISBN
978-91-628-7923-5
ISSN
0348-6672
Språk
eng
Metadata
Visa fullständig post

DSpace software copyright © 2002-2016  DuraSpace
gup@ub.gu.se | Teknisk hjälp
Theme by 
Atmire NV
 

 

Visa

VisaSamlingarI datumordningFörfattareTitlarNyckelordDenna samlingI datumordningFörfattareTitlarNyckelord

Mitt konto

Logga inRegistrera dig

DSpace software copyright © 2002-2016  DuraSpace
gup@ub.gu.se | Teknisk hjälp
Theme by 
Atmire NV