Transmission of bone conducted sound in the human skull based on vibration and perceptual measures

Abstract
For patients who are rehabilitated with bone conduction (BC) hearing aids, the position on the skull of the hearing aid is critical for the perception of the sound. The aim of this work was to describe the vibration of the cochlea from BC sound stimulation at different positions on the skull. The relevance of the vibration velocity of the cochlea as a perceptual measure was also investigated. In human cadavers vibration stimulation was applied at eight positions on each side of the skull with a frequency range of 0.1-10 kHz. The resulting velocity of the cochlear vibration was measured by a laser Doppler vibrometer from both ipsilateral and contralateral stimulation. A prototype of a novel bone conduction implant (BCI), positioned approximately 5 mm behind the ear canal, was tested with the same methodology. In live human subjects vibration stimulation was applied at four positions on the head. The resulting vibration velocity of the otic capsule was measured with a laser Doppler vibrometer. Bone conducted hearing thresholds in the same subjects were compared to the otic capsule vibration results. With vibration stimulation on the ipsilateral side there was an increased magnitude response of the cochlear vibration with shorter distance between the stimulation position and the cochlea. When the bone conducted stimulation was on the contralateral side the change in magnitude of the cochlear vibration between positions was limited. BC stimulation at a position close to the ipsilateral cochlea increased the response magnitude difference between the cochleae. The results of stimulating with a BCI and a transducer were similar. The influence of the squamosal suture on BC sound transmission was not clear but indications of a small damping effect were found. With simultaneous bilateral stimulation at the low frequencies correlated signals were added constructively or destructively while non-correlated signals gave a 3 dB sound energy increase. Time separation between ipsilateral and contralateral stimulation was found to be largest at positions close to the cochlea. The velocity response at the otic capsule from BC stimulation was similar between human cadavers and live humans. In live humans the correlation between vibration of the otic capsule and hearing perception was low at the individual level, while median data showed similar trends between the two methods. When BC sound stimulation is applied at a smaller distance between the stimulation position and the cochlea, sound transmission improves to the ipsilateral cochlea and is decreased to the contralateral cochlea. Measures of the vibration of the otic capsule from BC sound stimulation as an estimation of BC hearing perception was investigated and the results indicate that the method is valid. A patient with a hearing loss where there is an indication for BC hearing aids can likely benefit from increased ipsilateral stimulation, and also an improved binaural hearing from bilateral stimulation, when the hearing aid is applied close to the cochlea. The BCI is a realistic alternative to other BC hearing aids.
Parts of work
I: Eeg-Olofsson M, Stenfelt S, Tjellström A, Granström G. Transmission of bone-conducted sound in the human skull measured by cochlear vibrations. Int J of Audiol. 2008 Dec;47(12):761-9.::doi::10.1080/14992020802311216
 
II: Eeg-Olofsson M, Stenfelt S, Granström G. Implications for contralateral bone-conducted transmission as measured by cochlear vibrations. Otol Neurotol. 2011 Feb;32(2):192-8. ::doi:: 10.1097/MAO.0b013e318206fc1e
 
III: Håkansson B, Reinfeldt S, Eeg-Olofsson M, Östli P, Taghavi H, Adler J, Gabrielsson J, Stenfelt S, Granström G. A novel bone conduction implant (BCI): Engineering aspects and pre-clinical studies. Int J Audiol. 2010 Mar;49(3):203-15.::doi::10.3109/14992020903264462.
 
IV: Eeg-Olofsson M, Stenfelt S, Taghavi H, Reinfeldt S, Håkansson B, Finizia C. Transmission of bone conducted sound - correlation between hearing perception and cochlear vibration. Manuscript.
 
Degree
Doctor of Philosophy (Medicine)
University
University of Gothenburg. Sahlgrenska Academy
Institution
Institute of Clincial Sciences. Department of Otorhinolaryngology
Disputation
Fredagen den 13 april 2012, kl. 9.00, Hjärtats aula, Blå stråket 5, Sahlgrenska Universitetssjukhuset.
Date of defence
2012-04-13
E-mail
mans.eeg-olofsson@vgregion.se
URI
http://hdl.handle.net/2077/28248
Collections
  • Doctoral Theses / Doktorsavhandlingar Institutionen för kliniska vetenskaper
  • Doctoral Theses from Sahlgrenska Academy
  • Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
View/Open
Thesis frame (921.1Kb)
Abstract (43.22Kb)
Date
2012-03-23
Author
Eeg-Olofsson, Måns
Keywords
Bone conducted sound
Cochlear vibration
Hearing perception
Bone conduction implant
Publication type
Doctoral thesis
ISBN
978-91-628-8430-7
Language
eng
Metadata
Show full item record

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV