Show simple item record

dc.contributor.authorRomlin, Birgitta
dc.date.accessioned2013-12-10T08:11:33Z
dc.date.available2013-12-10T08:11:33Z
dc.date.issued2013-12-10
dc.identifier.isbn978-91-628-8753-7
dc.identifier.urihttp://hdl.handle.net/2077/33114
dc.description.abstractAbstract Background: Paediatric cardiac surgery has developed dramatically during the last decades. Today, a wide range of patients is operated on-from premature neonates to grown up children with congenital heart disease. Excessive bleeding during and after cardiac surgery is still common, and it is one of the most serious complications. In this thesis, we consider different aspects of monitoring of coagulation and platelet function during and after paediatric cardiac surgery. The aims were to determine (1) whether thromboelastometry analyses can be accelerated, (2) whether routine use of intraoperative thromboelastometry reduces perioperative transfusions, (3) whether platelet inhibition can be monitored with impedance aggregometry in children with systemic-to-pulmonary shunts, (4) how platelet count and function varies perioperatively, (5) whether ultrafiltration influences coagulation and platelet function, and (6) whether thromboelastometry detects clinically significant platelet dysfunction. Methods: Paediatric patients undergoing cardiac surgery were included in five pro-spective studies. Coagulation was assessed with standard laboratory tests and throm-boelastometry while platelet function was assessed with impedance aggregometry. Results: Thromboelastometry can be accelerated by performing the analysis before ultrafiltration and weaning of cardiopulmonary bypass, and by analyzing clot firmness after 10 minutes. Routine use of intraoperative thromboelastometry reduces the overall proportion of patients receiving transfusions (64% vs. 92%, p < 0.001). Impedance aggregometry can be used to monitor anti-platelet effects of acetyl salicylic acid after shunt implantation in paediatric patients. A substantial proportion of the patients are outside the therapeutic range 3-6 months after surgery. There are substantial reduc-tions both in platelet count and platelet function during and immediately after surgery. Platelet function, but not platelet count, recovers during the first 24 hours after sur-gery. Ultrafiltration has no or limited effect on platelet count, platelet function, and thromboelastometry analyses. Thromboelastometry has acceptable ability to detect intraoperative but not postoperative ADP-induced platelet dysfunction. Conclusion: Monitoring of coagulation and platelet function gives important information about haemostatic disturbances during and after paediatric cardiac surgery. Routine monitoring of the coagulation markedly reduces transfusion requirements in pae-diatric cardiac surgery. After surgery, more specific platelet tests are necessary to assess platelet function. Key words: paediatric cardiac surgery, haemostasis, platelet, coagulation, thromboe-lastometry, impedance aggregometry, coagulopathy, haemoconcentration ISBN 978-91-628-8753-7 Gothenburg 2013sv
dc.language.isoengsv
dc.relation.haspartI Earlier detection of coagulopathy with thromboelastometry during pediatric cardiac surgery: a prospective observational study. Romlin BS, Wåhlander H, Synnergren M, Baghaei F, Jeppsson A. Paediatr Anaesth. 2013 Mar;23(3):222-7. Epub 2013 Jan 10. ::PMID::23302040sv
dc.relation.haspartII Intraoperative thromboelastometry is associated with reduced transfusion prevalence in pediatric cardiac surgery. Romlin BS, Wåhlander H, Berggren H, Synnergren M, Baghaei F, Nilsson K, Jeppsson A. Anesth Analg. 2011 Jan;112(1):30-6. Epub 2010 Nov 3. ::PMID::21048096sv
dc.relation.haspartIII Monitoring of acetyl salicylic acid-induced platelet inhibition with impedance aggregometry in children with systemic-to-pulmonary shunts. Romlin BS, Wåhlander H, Strömvall-Larsson E, Synnergren M, Baghaei F, Jeppsson A. Cardiol Young. 2013 Apr;23(2):225-32. Epub 2012 Jun 12. [PubMed - in process] ::PMID::22691184sv
dc.relation.haspartIV. Romlin BS, Söderlund F, Wåhlander H, Nilsson B, Baghaei F, Jeppsson A. Platelet count and function in paediatric cardiac surgery: A prospective observational study. Submitted.sv
dc.relation.haspartV. Romlin BS, Wåhlander H, Hallhagen S, Baghaei F, Jeppsson A. Perioperative monitor-ing of platelet function in paediatric cardiac surgery: Thrombo¬elastometry, platelet aggregometry or both? Manuscript.sv
dc.subjectpaediatric cardiac surgerysv
dc.subjecthaemostasissv
dc.subjectplateletsv
dc.subjectcoagulationsv
dc.subjectthromboelastometrysv
dc.subjectimpedance aggregometrysv
dc.subjectcoagulopathysv
dc.subjecthaemoconcentrationsv
dc.titleMonitoring of coagulation and platelet function in paediatric cardiac surgerysv
dc.typetexteng
dc.type.svepDoctoral thesiseng
dc.gup.mailbirgitta.romlin@vgregion.sesv
dc.type.degreeDoctor of Philosophy (Medicine)sv
dc.gup.originUniversity of Gothenburg. Sahlgrenska Academysv
dc.gup.departmentInstitute of Medicine. Department of Molecular and Clinical Medicinesv
dc.gup.defenceplaceOnsdagen den 4 december 2013, kl. 13.00, Hörsal Tallen, Drottning Silvias Barn och Ungdomssjukhus, Rondvägen 10, Göteborgsv
dc.gup.defencedate2013-12-04
dc.gup.dissdb-fakultetSA


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)