• English
    • svenska
  • svenska 
    • English
    • svenska
  • Logga in
Redigera dokument 
  •   Startsida
  • Sahlgrenska Academy / Sahlgrenska akademin
  • Institute of Neuroscience and Physiology / Inst för neurovetenskap och fysiologi
  • Doctoral Theses / Doktorsavhandlingar Institutionen för neurovetenskap och fysiologi
  • Redigera dokument
  •   Startsida
  • Sahlgrenska Academy / Sahlgrenska akademin
  • Institute of Neuroscience and Physiology / Inst för neurovetenskap och fysiologi
  • Doctoral Theses / Doktorsavhandlingar Institutionen för neurovetenskap och fysiologi
  • Redigera dokument
JavaScript is disabled for your browser. Some features of this site may not work without it.

Aspects on Function in Age-Related Macular Degeneration

Sammanfattning
Age-related macular degeneration (AMD) is one of the leading causes of severe visual loss among persons ≥ 60 years. AMD can be categorized in one of three stages: early, intermediate, or late. In early AMD visual symptoms are inconspicuous whereas, in the late stage, severe loss of vision is common. Late AMD has dry and wet forms. Wet AMD is a chronic disease with episodes of exacerbation, with varying intervals between relapses. The sooner a new episode of disease activity is discovered and treated the better for the visual outcome while delayed treatment often leads to irreversible loss of visual function. Providing timely diagnosis and treatment poses a difficult challenge for ophthalmology clinics today. Measurement of visual resolution by using conventional distance acuity charts is inadequate for the detection of early functional changes in AMD and also for monitoring the progression in the disease. A key problem is associated with the optotype test targets and their information overload. Optotypes are many times larger than the retinal functional units, the receptive fields, and viewing time is usually unrestricted. There is a need for new sensitive tests of vision to uncover low degrees of visual impairment in AMD and for allowing self-testing of vision in patients treated for wet AMD. There is also a need for simplified and standardized reading tests to gain insight into an important task of daily life, reading performance. The aims of this thesis was to evaluate new vision tests designed for the detection and grading of lesions in the macula and to study if these tests are suitable for self-testing of vision. Further, a new abbreviated and standardized reading test was studied. Methods: In prospective studies on AMD patients and normal subjects new tests of vision were evaluated. The tests in paper I-III are based on Rarebit testing which is able to detect gaps in the receptive fields, using bright microdots on a dark background. The tests were gradually refined from mini data projectors and personal computers to a unique application for smartphone, including the possibility of self-testing of vision and transmission of results. The reading test evaluated in paper IV was also in the form of a smartphone application. Results: The new tests of vision evaluated in paper I-III capture macular deficits hidden to conventional acuity tests. The new reading test evaluated in paper IV measures basic reading abilities at least as good as conventional and more time-consuming Conclusions: By using new more sensitive tests which appear to have good potential for effective self-testing of vision in AMD, some currently performed hospital-based controls may be replaced with self-tests at home. This may contribute to a more effective use of healthcare resources. The new reading test demonstrates a new approach towards meaningful and time-efficient assessment of reading ability.
Delarbeten
I. Christina Winther, Lars Frisén: A compact rarebit test for macular diseases. Br J Ophthalmol 2010; 94: 324-327. ::doi::10.1136/bjo.2009.164749
 
II. Christina Winther, Lars Frisén: New rarebit vision test captures macular deficits hidden to acuity tests. Acta Ophthalmol 2015; 93: 481-485. ::doi::10.1111/aos.12659
 
III. Christina Winther, Lars Frisén: Self-Testing of Vision in Age-Related Macula Degeneration: A Longitudinal Pilot Study Using a Smartphone-Based Rarebit Test. J Ophthalmol 2015 June 1. ::doi::10.1155/2015/285463
 
IV. Christina Winther, Lars Frisén: Assessment of spot reading capacity in patients with age-related macular degeneration using printed charts and a new smartphone-based reading test. Manuscript.
 
Examinationsnivå
Doctor of Philosophy (Medicine)
Universitet
University of Gothenburg. Sahlgrenska Academy
Institution
Institute of Neuroscience and Physiology. Department of Clinical Neuroscience and Rehabilitation
Disputation
Fredagen den 29 januari 2016, kl.09.00, Mölndalsaulan (V-huset), Mölndals sjukhus
Datum för disputation
2016-01-29
URL:
http://hdl.handle.net/2077/40885
Samlingar
  • Doctoral Theses / Doktorsavhandlingar Institutionen för neurovetenskap och fysiologi
  • Doctoral Theses from Sahlgrenska Academy
  • Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
Fil(er)
Thesis frame (10.76Mb)
Abstract (729.9Kb)
Datum
2016-01-08
Författare
Winther, Christina
Nyckelord
age-related macular degeneration
macula
macular oedema
rarebit
reading test
reading speed
self-test
smartphone application
vision test
visual acuity
Publikationstyp
Doctoral thesis
ISBN
978-91-628-9677-5 (PDF)
978-91-628-9676-8 (PRINT)
Språk
eng
Metadata
Visa fullständig post

DSpace software copyright © 2002-2016  DuraSpace
gup@ub.gu.se | Teknisk hjälp
Theme by 
Atmire NV
 

 

Visa

VisaSamlingarI datumordningFörfattareTitlarNyckelordDenna samlingI datumordningFörfattareTitlarNyckelord

Mitt konto

Logga inRegistrera dig

DSpace software copyright © 2002-2016  DuraSpace
gup@ub.gu.se | Teknisk hjälp
Theme by 
Atmire NV