Pulse-Synchronous Intramuscular Pressure Oscillations

Clinical and experimental studies

Sammanfattning
Background Intramuscular pressure (IMP) is measured in studies of tissue nutrition and in the diagnosis of compartment syndromes. Patients with compartment syndromes have an elevated IMP due to increased volume in a muscle compartment. In patients with exercise-induced leg pain, the measurement of IMP is commonly regarded as the gold standard in diagnosing chronic anterior compartment syndrome (CACS). However, recent studies have reported that IMP as a parameter in diagnosing CACS needs to be improved. Oscillations of the IMP deriving from arterial pulsations have previously been detected in muscles with abnormally elevated IMP. The relationship between the amplitude of the IMP oscillations and the absolute IMP is, however, unknown. Aims The aims of the thesis were therefore to investigate the relationship between the IMP and the amplitude of the pulse-synchronous IMP oscillations and to evaluate the potential of using pulse-synchronous IMP oscillations in diagnosing compartment syndromes. Methods Pulse-synchronous IMP oscillations were studied at normal levels of IMP at rest, during experimental models of abnormally elevated IMP and at rest after exercise. The amplitude of the oscillations was measured in healthy subjects, patients with CACS and in patients with leg pain for reasons other than CACS. Results The amplitude of the IMP oscillations was higher for the CACS patients compared with the control subjects and patients with leg pain for reasons other than CACS. During simulated compartment syndrome, the oscillations were observed in the entire IMP range seen in patients with chronic and acute compartment syndromes. The amplitude of the IMP oscillations varied with the absolute level of the IMP. The largest amplitudes were recorded when the level of the IMP was close to the level of the mean arterial pressure and the local perfusion pressure approached zero. The amplitude of the oscillations is a parameter with high sensitivity and specificity that may lend support when diagnosing CACS. Among the CACS patients, women had an 11 mmHg lower IMP at rest after exercise compared with men (p < 0.01). The magnitude of the difference may be of clinical importance. The amplitude of the IMP oscillations did not differ significantly between men and women (p > 0.5). The fluid injections used with traditional needle-injection techniques influences the measured IMP. Even small amounts of saline constitute a measurement problem, rendering an overestimated IMP reading. Fiberoptic pressure-measurement techniques may therefore improve IMP measurements. Conclusion The amplitude of the pulse-synchronous IMP oscillations reflects the IMP and the pathophysiological foundation in compartment syndromes. The patency of the catheter and the validity of the IMP measurement is assured when pulse-synchronous IMP oscillations are recorded. The amplitude has high sensitivity and specificity in identifying CACS patients. It may be an additional parameter in both research and diagnosing compartment syndromes.
Delarbeten
I. Nilsson, A. et al. Evaluation of a fiberoptic technique for recording intramuscular pressure in the human leg, Journal of Clinical Monitoring and Computing, 2015:1-7 ::PMID::26271511
 
II. Nilsson, A.et al. The amplitude of pulse-synchronous oscillations varies with the level of intramuscular pressure in simulated compartment syndrome. Journal of Experimental Orthopaedics, 2015;2(1):3. ::DOI:: 10.1186/s40634-015-0020-6
 
III. Nilsson, A. et al. Using the Amplitude of Pulse-Synchronous Intramuscular Pressure Oscillations When Diagnosing Chronic Anterior Compartment Syndrome. Orthopaedic Journal of Sports Medicine, 2014;2(11):2325967114556443. ::PMID::26535284
 
IV. Nilsson, A. et al. The Amplitude of Intramuscular Pressure Oscillations in Compartment Syndrome Manuscript. Submitted, 2015
 
Examinationsnivå
Doctor of Philosophy (Medicine)
Universitet
University of Gothenburg. Sahlgrenska Academy
Institution
Institute of Clincial Sciences. Department of Orthopaedics
Disputation
Fredagen den 29 januari 2016, kl. 9.00, Hörsal Arvid Carlsson, Academicum, Medicinaregatan 3, Göteborg
Datum för disputation
2016-01-29
E-post
andreas7nilsson@gmail.com
andreas.nilsson@orthop.gu.se
URL:
http://hdl.handle.net/2077/40888
Samlingar
  • Doctoral Theses / Doktorsavhandlingar Institutionen för kliniska vetenskaper
  • Doctoral Theses from Sahlgrenska Academy
  • Doctoral Theses from University of Gothenburg / Doktorsavhandlingar från Göteborgs universitet
Fil(er)
Thesis frame (3.008Mb)
Abstract (140.2Kb)
Datum
2016-01-12
Författare
Nilsson, Andreas
Nyckelord
compartment syndrome
chronic anterior compartment syndrome
intramuscular pressure
pulse-synchronous oscillations in intramuscular pressure,
intramuscular arterial pulsations
fiber-optic technique
Publikationstyp
Doctoral thesis
ISBN
ISBN 978-91-628-9674-4 (Print)
ISBN 978-91-628-9675-1 (Pdf)
Språk
eng
Metadata
Visa fullständig post

DSpace software copyright © 2002-2016  DuraSpace
gup@ub.gu.se | Teknisk hjälp
Theme by 
Atmire NV
 

 

Visa

VisaSamlingarI datumordningFörfattareTitlarNyckelordDenna samlingI datumordningFörfattareTitlarNyckelord

Mitt konto

Logga inRegistrera dig

DSpace software copyright © 2002-2016  DuraSpace
gup@ub.gu.se | Teknisk hjälp
Theme by 
Atmire NV