Passive sampling of PAHs and some trace organic compounds in occupational and residential air: needs, evaluation and limits
Sammanfattning
Human exposure to elevated levels of polycyclic aromatic hydrocarbons (PAHs) and trace organic compounds (e.g. PCB, OCP, PBDE) can be related to negative health effects. This raises demands of exposure measurements to be performed. Passive air samplers (PAS) are simple and cheap sampling options that may be useful tools for exposure screening of large populations. They can also enable frequent monitoring. The aim of this thesis was to evaluate and increase the understanding of PAS methods to sample and monitor PAHs and some trace organic compounds in occupational and residential air.
A polyurethane foam (PUF) based PAS was considered having the best potential and was chosen for the evaluation. Two designs of this PUF-PAS were evaluated: one for stationary sampling shaped as a disk and one for personal sampling shaped as a cylinder (“mini-PUF”).
The results presented show that PUF-PAS disks and mini-PUFs provide detectable levels for most of the studied compounds under typical occupational and residential air concentrations. They also showed potential to detect spatial differences in concentrations between and within sampling sites as well as inside and outside homes. The novel use of the mini-PUF was successful both as stationary and personal sampler. Moreover, the precision of gas phase PAHs in replicates of PUF-PAS disks and mini-PUFs were comparable to precision for active samplers while particle-associated PAHs showed more variable results. Results from personally deployed mini-PUFs were significantly correlated to personal active samplers for the studied compounds and the accuracy was high for most compounds.
Sampling rates (RS) for 16 individual PAHs ranged from 1 to 10 m3 day-1 (0.7-7 L min-1) in PUF-PAS disks, from 0.4 to 3.3 m3 day-1 (0.3-2.3 L min-1) in mini-PUFs deployed for two weeks as well as 8 h. No significant differences in RS were found for PAHs in the gas phase and PAHs associated to particles. The RS was higher for the mini-PUF compared to the PUF-PAS disk when correcting for their surface areas indicating a more efficient uptake in the mini-PUF design. Somewhat higher RS was also found for gas phase PAHs for the 8 h exposure compared to two weeks exposure.
In conclusion, this thesis demonstrates that PUF-PAS disks can be a useful tool for screening of PAH concentrations in occupational environments. The mini-PUF has a good potential to be used as a personal sampler for PAHs in occupational environments but requires further validation.
Delarbeten
I. Bohlin, P., Jones, K. C. and Strandberg, B. “Occupational and indoor air exposure to persistent organic pollutants: A review of passive sampling techniques and needs.” Journal of Environmental Monitoring 2007; 9:501-509. ::doi::10.1039/b700627f II. Bohlin, P., Jones, K. C., Tovalin, H., and Strandberg, B. “Observations on persistent organic pollutants in indoor and outdoor air using passive polyurethane foam samplers.” Atmospheric Environment 2008; 42:7234-7241. ::doi::10.1016/j.atmosenv.2008.07.012 III. Bohlin, P., Jones, K. C. and Strandberg, B. “Field evaluation of polyurethane foam passive air samplers to assess airborne PAHs in occupational environments.” Environmental Science & Technology 2010; 44 (2):749-754. ::doi::10.1021/es902318g IV. Bohlin, P., Jones, K. C., Levin J-O., Lindahl R. and Strandberg, B. “Field evaluation of a personal passive air sampler for PAH exposure in workplaces”. Journal of Environmental Monitoring 2010; Accepted
Examinationsnivå
Doctor of Philosophy (Medicine)
Universitet
University of Gothenburg. Sahlgrenska Academy
Institution
Institute of Medicine. Department of Public Health and Community Medicine
Disputation
Fredagen den 28 maj, kl. 9.00, Hörsal Karl Isaksson, Arbets- och miljömedicin, Medicinaregatan 16 A, Göteborg
Datum för disputation
2010-05-28
E-post
pernilla.bohlin@amm.gu.se
Datum
2010-05-11Författare
Bohlin, Pernilla
Nyckelord
passive air sampling
PAH
POP
occupational environment
residential environment
exposure
stationary air sampling
personal air sampling
PUF
evaluation
Publikationstyp
Doctoral thesis
ISBN
978-91-628-8066-8
Språk
eng